Correction to: Precise, accurate and user-independent blood collection system for dried blood spot sample preparation

Analytical and Bioanalytical Chemistry, Apr 2018

Ricardo Neto, Andrew Gooley, Michael C. Breadmore, Emily F. Hilder, Florian Lapierre

A PDF file should load here. If you do not see its contents the file may be temporarily unavailable at the journal website or you do not have a PDF plug-in installed and enabled in your browser.

Alternatively, you can download the file locally and open with any standalone PDF reader:

https://link.springer.com/content/pdf/10.1007%2Fs00216-018-1100-0.pdf

Correction to: Precise, accurate and user-independent blood collection system for dried blood spot sample preparation

Correction to: Precise, accurate and user-independent blood collection system for dried blood spot sample preparation Ricardo Neto 0 1 2 3 Andrew Gooley 0 1 2 3 Michael C. Breadmore 0 1 2 3 Emily F. Hilder 0 1 2 3 Florian Lapierre 0 1 2 3 Emily F. Hilder 0 1 2 3 Florian Lapierre 0 1 2 3 0 Trajan Scientific and Medical , 7 Argent Place, Ringwood, Victoria 3134 , Australia 1 ARC Training Centre for Portable Analytical Separation Technologies (ASTech) , Hobart , Australia 2 Future Industries Institute, University of South Australia , GPO Box 2471, Adelaide, South Australia 5095 , Australia 3 Australian Centre for Research on Separation Science, School of Natural Sciences, University of Tasmania , Private Bag 75, Hobart, Tasmania 7001 , Australia - In the section BVolumetric measurement^ the sentence BTo validate the accuracy and precision of the three dispensing methodologies (manual pipette, digital syringe and glass capillary), volumetric measurements were performed with the VMS Artel system^ should read BTo validate the accuracy and precision of the three dispensing methodologies (manual pipette, digital syringe and glass capillary), volumetric measurements were performed with the PCS® Artel system^. The authors would like to call the reader’s attention to the following: The instrument they used to measure the volumetric precision of the dispensing devices is not called BVMS^ but BPCS®^. Therefore, the following sentences would need to be changed in the original publication: In the section BReagents and materials^ the sentence BA dual-dye ratiometric photometry volume measurement system (VMS) was bought from Artel (USA)^ should read BA dual-dye ratiometric photometry pipette calibration system (PCS® - part number PCS-103-07A) was bought from Artel (USA)^. – The online version of the original article can be found at https://doi.org/ 10.1007/s00216-018-0993-y


This is a preview of a remote PDF: https://link.springer.com/content/pdf/10.1007%2Fs00216-018-1100-0.pdf

Ricardo Neto, Andrew Gooley, Michael C. Breadmore, Emily F. Hilder, Florian Lapierre. Correction to: Precise, accurate and user-independent blood collection system for dried blood spot sample preparation, Analytical and Bioanalytical Chemistry, 2018, 1-1, DOI: 10.1007/s00216-018-1100-0